c .Specification LCD Module 4U et he aST - 5 1 4 4 0 G L 0 7 0 H U - F W - A C at .D Table of Contents w
Type No. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12.
om
First Edition
Approved by
Production
June 20, 2002
Final Revision
Checked by
Quality Assurance
Checked by
Engineering
*******
Drawn by DIV Engineering
Application ...........................................................................................2 Mechanical Specification .....................................................................2 Absolute Maximum Ratings................................................................3 Environment Condition........................................................................3 Optical Characteristics .........................................................................4 Electrical Characteristics ...................................................................10 Product Standard................................................................................19 Reliability Test...................................................................................22 Code System of Production Lot........................................................24 Packing Specification .........................................................................25 Product handling Cautions ................................................................26 Condition for Guarantee....................................................................27
Revision History
Rev. Date Page
w
w
.D w
t a
S a
e h
t e
U 4
.c
m o
Comment
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
w
w
w
.D
a
aS t
ee h
4U t
om .c
Page 1/27
1.Application
This specification applies to 7.0" color TFT-LCD module (T-51440GL070HU-FW-AC). The applications of the panel are for automotive entertainment and car navigation.
2.Mechanical Specifications
Screen Size Display Mode Driving Method : : : 7 inches (18cm) diagonal Normally White a-Si TFT active matrix format Line Scan/non-interlace Reverse Horizontal Line TFT Cell, Driver IC, Timing controller IC, Backlight unit, Inverter DC/DC Converter, and Video circuit +8V-16V(DC) Composite Video Signal (NTSC/PAL) or Specific Analog RGB signal (NTSC/PAL) + Composite or Separate Synchronized signal Horizontal/Vertical Synchronized signal (negative) 480(W) x 234(H) 1440(W) x 234(H) 0.3210(W) x 0.3720(H) mm RGB Stripe 154.08(W) x 87.048(H) mm Triple wavelength L-shaped Cold Cathode Fluorescent Lamp, Dimming Ratio 1-100% 12 O'clock (Maximum Contrast) AGLR Coating (Low Reflectance) 164.9(W) x 101.9(H) x 23.1(D) mm TBD g max.
Composition
:
Input Power Supply Input Signal
: :
Output Signal Resolution Dot Resolution Dot Pitch Pixel Configuration Active Area Backlight
: : : : : : :
Viewing Direction Surface Treatment Outer Dimension Weight Attached Drawing
: : : :
: Dimensional Outline UE-210547-00
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 2/27
3.Absolute Maximum Ratings
Item Power Supply Video Circuit Backlight Composite Video Analog RGB Synchronous Signals Input Signal Chroma Signal Adjustment Signals Switching Signals Storage Temperature Operating Temperature Symbol VPW VBL VIDEO R,G,B VSY,HSY CYSYNC COLOR, BRT,CONT, TINT,DIM Ta=255? Vss=0V U/D,R/L, MOD1~ 3, VPW=VBL=+12.0V N/P,R/CMP, YC/CMP Tstg Topr Ta=255? 75O VPW=VBL=+12.0V Conditions Ta=255? VSS=0V Min. Vss-0.2 Vss-0.2 - - Vss-0.3 Max. 16.0 16.0 1.5 1.5 1.5 1.5 VDD+0.3 Unit V V VP-P VP-P VP-P VP-P V
Vss-0.3
VDD+0.3
V
-40 -30
+85 +85
? ?
Note: Absolute maximum ratings should not exceed the limit anytime. If the product exceeds the limit, it may cause damage. Please be cautious to the changes in supply voltage, connection parts, surge of signals and ambient temperature.
4.Operating Conditions
Item Operating Temperature Range LCD Module w/Backlight LCD Panel Storage Temperature Range LCD Module w/Backlight LCD Panel Conditions Ambient Temperature (Panel Surface) Surface Temperature Surface Temperature Surface Temperature Tmperature Range -30~ 85? ( -30~ 85? ) -30~ 75? Note4-3 -40~ 85? -40~ 85? Remark Note4-1,4-2
Note4-1: Operating temperature range defines the operation only and the contrast, response time and other display optical characteristics are set at Ta=+25? . Note4-2: Panel surface temperature indicates the temperature of the backlight panel surface on the five points from the four corners and the center. Also note that the panel temperature of backlight side is 10? (reference value) higher than the other side. Note4-3: Backlight is not activated.
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 3/27
5.Optical Specifications
Item (1)Brightness (2)Contrast Symbol B CR X (3)White Chromaticity (4)Brightness Uniformity (5)Vertical Up Y ? ? F f
U D L R
Conditions ? 0 f 0 C
Standard Value Min. 60 0.265 0.300 0.7 Typ. (400) 150 0.305 0.340 (60) (30) (60) (60) TBD TBD Max. 0.345 0.380 TBD TBD
Unit Cd/m2 -
Method of Remark Measure Note5-1
Optimum Viewing
(Fig.5-1) Degree Degree Degree Degree ms Ms (Fig.5-4) (Fig.5-3) (Fig.5-2)
0 0 0 0 0 0 0
0 0 0 0 ? 10 0 ? 10 0 0 ? 10 ? 10
Viewing Angle Down (6)Horizontal Left
Viewing Angle Right (7)Response Time Rise Decay
tr td
Note5-1: Under the condition of tube current 6.0m A ? Conditions for Measuring ? Environment: Dark room with no light or close to no light. ? Temperature: 2 5 5 ? ? Humidity: 4 0 ~ 7 0 % R H ? After backlight has been lit more then 30 minutes, driving voltage is set for optimal contrast to measure center of display. ? Measure by the specified inverter or similar product. ? Optimal viewing angle (The angle with best contrast)
12 O'clock
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 4/27
( Fig.5 - 1 ) ? Method of Brightness Measurement ( 1 ) Measuring Device TOPCON BM-7?Measuring Field:1 ( 2 ) Measuring Point Center of Display ? = 0 ? f = 0 On condition ? : A vertical angle from measuring direction to perpendicular. f : A horizontal angle from measuring direction to perpendicular.
Center
(Pixel)
(X,Y)=(240,117)
LCD Module
Distance : 5 0 0 m m
TOPCON BM-7
( 3 ) Method of Measuring Apply signal voltage (displayed in white) to maximize brightness and measure brightness B (cd/m2 ). The distance between BM-7's front lens to surface panel is 500mm. Measured after backlight has been lit for more than 30 minutes. ? Method of Contrast Measurement ( 1 ) Measuring Device TOPCON BM-7?Measuring Field:1 ( 2 ) Measuring Point Center of display: same as Method of Brightness Measurement Method of Measuring (3) * Set LCD module to? = 0 ? f = 0 . * Change signal voltage to measure maximum brightness Y1 and minimum brightness Y2. * Contrast is derived from CR=Y1/Y2.
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 5/27
( Fig.5 - 2 ) ? Definition of Brightness Uniformity Definition is calculated from the four points (S0-S4) on the diagram below.
20mm
20mm
20mm S1 S4
S0
S2
S3 20mm
Minimum Value of S1-S4 Standard Value of Brightness Uniformity= S0
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 6/27
( Fig.5 - 3 ) ? Method of Viewing Angle Measurement ( 1 ) Measuring Device TOPCON BM-7?Measuring (2)
Field:1
Measuring Point Center of display : Same as Method of Brightness Measurement Angle of Measuring ? : An angle vertical to perpendicular line from the viewing direction. F : An angle horizontal to perpendicular from the viewing direction.
(3)
Temperature
Rotation Table (,)
TOPCON BM-7
f
LCD
?
Computer
Control Unit & Waveform Generator
( 4 ) Method of Measuring Set rotation table tof = 0 and set BM-7 to contrast 10 to measure angle? for left and right direction of horizontal viewing anglef . Also set rotation table tof = 9 0 and set BM-7 to contrast 10 to measure angle? for up and down direction of vertical viewing angle ? .
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 7/27
( Fig.5 - 4 ) ? Measuring Response Time ( 1 ) Measuring Device TOPCON BM-7?Measuring Field:1 Tektronix Digital Oscilloscope ( 2 ) Measuring Point Center of display, same as Method of Brightness Measurement ( 3 ) Method of Measuring * Set LCD panel to? = 0 ,and f = 0 . * Input white? black? white to display by switching signal voltage. * If the luminance is 0% and 100% immediately before the change of signal voltage, thent r is optical response time during the change from 90% to 10% immediately after rise of signal voltage, andt d is optical response time during the change from 10% to 90% immediately after decay of signal voltage.
White
Black
White
100% 90%
Brightness
10% 0% tr td
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 8/27
6. Electrical Characteristics 6.1 Recommended Operating Conditions
( T a = 255? ? V ss= 0V) Item Power Supply System Backlight Composite Video Analog RGB Chroma Signal Synchronous Signals Input Signals Brightness Tint Color Contrast Backlight Select Signals BRT TINT COLOR CONT DIM MOD1~ 3,N/P U/D,R/CMP R/L,YC/CMP fVDN NTSC fHDN Synchronous Frequency fVDP PAL fHDP 15.20 15.625 16.00 KHz Note: Recommended Operating Conditions defines the guaranteed range of operation and it is out of guarantee if the product exceeds the range even if within the range of Item3.Absolute Maximum Ratings. Please use within the range of Recommended Operating Conditions. 48.64 50.00 51.20 Hz 15.00 15.734 16.50 KHz H level L level 1 3.0 0 57.14 59.939 1.0 2.6 2.7 2.5 2.5 100 3.6 V 0.8 62.86 Hz V V V V % Symbol VPW VBL VIDEO R,G,B YCSYNC HSY,VSY 75O Condition Min. 8.0 8.0 Typ. 12.0 12.0 1.0 0.7 1.0 0.7 Max. 16.0 16.0 Unit V V Vp-p Vp-p Vp-p Vp-p
6.2 Pixel Alignment
BRGBRGB RGB RG GBRGBRGB RGB RGB RGBRGBRGB RGB RGBR RGBRGBRGB RGB RGBR RGBRGBRGB RGB RGBR RGBRGBRGB RGB RGBR GBRGBRGB RGB RGB BRGBRGB RGB RG
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 9/27
6.3 I/O Terminal Descriptions
No. 1 2 3 4 5 6 7 8 9 10 11 Symbol VDD COLOR BRT CONT VIDEO Vss Vss Vss VBL VBL U/D Level ? ? ? ? ? ? ? ? ? ? H/L Power Supply (+5V) Color Adjustment (0~ 5V) Brightness Adjustment (0~ 5V) Contrast Adjustment (0~ 5V) Composite Video Signal Input (1.0VP-P,75O ) Signal Ground Backlight Ground Backlight Ground Power Supply for Backlight (+8~ 16V) Power Supply for Backlight (+8~ 16V) Up/Down Scanning Direction
(Open:Down to Up, GND:Up to Down)
Function
I/O Output Input Input Input Input ? ? ? Input Input Input
Remark
12 13 14 15 16 17 18 19
R/L DIM MOD1 MOD2 MOD3 N/P TINT R/CMP
H/L ? H/L H/L H/L H/L ? H/L
Left/Right Scanning Direction
(Open: Left to Right, GND: Right to Left)
Input Input Input Input Input Input Input Input
Backlight Dimming (1~ 100% Adjustable) Display Mode 1 Display Mode 2 Display Mode 3 NTSC/PAL Select (Open : NTSC, GND : PAL) Tint Adjustment (1~ 5V) RGB/Composite Select
(Open: RGB, GND:Composite)
20 21 22 23 24 25 26 27 28 29 30
YC/CMP YCSYNC VSY HSY Vss G B R VPW VSYO HSYO
H/L ? ? ? ? ? ? ? ? ? ?
Synchronous Signal Select
(Open: YC Separate, GND: Composite)
Input Input Input Input ? Input Input Input Input Output Output
Chroma Signal (0.7VP-P,75O ) Vertical Sync. (0.7VP-P,75O , Active Low) Horizontal Sync. (0.7VP-P,75O , Active low) Signal Ground Green Color Video Signal (1.0VP-P,75O ) Blue Color Video Signal (1.0VP-P,75O ) Red Color Video Signal (1.0VP-P,75O ) System Power Supply (+8~ 16V) Vertical Sync.Output (0.7VP-P,75O ,Active Low) Horizontal Sync.Output (0.7VP-P,75O ,Active Low)
Mating Connector : SHDR-30V-S-B (JST)
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 10/27
6.4 Block Diagram
YCSYNC YC/CMP R/CMP VSY HSY R,G,B VIDEO COLOR BRT CONT TINT N/P HSYO
Video Controller
R,G,B VCOM
7 inch Wide TFT LCD Module
VSYO Dip SW MOD1~ 3 R/L U/D
Timing Controller
OEV FX OE CLK
VPW
DC/DC Converter
-5V +3.3V +5V +7V
+18.5V -12.0V +5V +3.3V
DIM
Brightness Control
VBL
Inverter
HOT GND
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 11/27
6.5 Signal Definition
Pin No. 1 Symbol VDD Function 5V output terminal Please use this for each adjustable terminal (2 ~ 4, 18 pin) Color adjustment input terminal. Can be selected to change anywhere between 0 ~ 5V. I/O Intermal Equivalent Circuit Output Current(Idd) = Less than 10mA
2
COLOR
+5V
60k 100 200 24k 40k 40k
-5V
GND
3
BRT
Brightness Adjustment for RGB signal. Can be selected to change anywhere between 0 ~ 5V.
+5V
10k 100 200 75k
-5V
GND
4
CONT
Contrast adjustment terminal. Can be selected to change anywhere between 0 ~ 5V.
+5V
50k 100 200 20k
40k
-5V
GND
5
VIDEO
Composite video signal input terminal. Please use standard input level 1 Vp-p of composite video signal. When using composite video input signal fix YCSYNC(21pin) to GND . Signal Ground terminal. Connect to GND. Backlight grounding terminal. Connect to GND. Backlight grounding terminal. Connect to GND. Power supply input terminal for backlight. Use standard 12V. Power supply input terminal for backlight. Use standard 12V. Up/Down scanning direction select terminal. When open, it will scan down to up. When connected to GND, it will scan up to down. Left/Right scanning direction select terminal. When open, it will scan left to right. When connected to GND, it will scan right to left.
+5V
1uF
75
-5V
GND
6 7 8 9 10 11
Vss Vss Vss VBL VBL U/D
100
12
R/L
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 12/27
Pin No. 13 14 15 16 17
Symbol DIM MOD 1 MOD 2 MOD 3 N/P
Function Backlight Dimming Terminal. Input 3.3V square wave PWM format Display mode select input terminal See Table 6.1
I/O Intermal Equivalent Circuit
+3.3V
22k 100
NTSC/PAL select terminal. Open : NTSC GND : PAL Tint adjustment input terminal. Can be selected between 1~5V
100
+3.3V
22k
18
TINT
+5V
25k 200 35k
40k -5V
GND
19
R/CMP
Video signal input select terminal. Open: Analog RGB GND: Composite Video
+5V 4.7k 4.7k 100 200 30k 1k 36k -5V GND
20
YC/CMP Synchronous signal input select terminal. Open: YC seperate input GND: Composite YCSYNC Chroma input terminal. Use Chroma signal 0.7Vp-p. When using composite video, connect to GND. VSY Vertical synchronous signal input terminal. HSY Horizontal synchronous signal input terminal.
+5V
YC/CMP 5k YCSYNC 0.1uF 200
21
75
-5V
GND
22 23
+3.3V 2k
22k 10uF
+
0.1uF
22k 100 GND
24 25 26 27
Vss G B R
Signal Ground terminal. Connect to GND. Analog RGB signal input terminal. Use Analog RGB signal standard level 0.7Vp-p.
75
+5V
0.1uF
-5V
GND
28
PWR
System power supply input terminal. Use standard 12V. Vertical synchronous signal output terminal. Please use for UOS(under on screen) to adjust the screen position.
100
29
VSYO
30
HSYO
Horizontal synchronous signal output terminal. Please use for UOS(under on screen) to adjust the screen position.
OPTREX CORPORATION Page 13/27
T-51440GL070HU-FW-AC
OPTREX
Mode
Table 6.1 : Display Mode Display Image MOD1 MOD2 (4:3 Signal Input) (14pin) (15pin)
MOD3 (16pin)
Remark Input Signal is displayed fully on screen.
Full
GND
GND
GND
Normal Center
OPEN
GND
4:3 Image displayed in center of GND display. 4:3 Signal has been extended sideways from center of GND display. Display is fixed on top and then GND zoomed. The time for gate is adjusted from Zoom1 mode.
Wide
GND
OPEN
Zoom 1
OPEN OPEN
Zoom 2
GND
GND
OPEN
4:3 image shifted to left.
Normal Left
OPEN
GND
OPEN
4:3 image shifted to right.
Normal Right
GND
OPEN OPEN
Unfixed
Unfixed
OPEN OPEN OPEN
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 14/27
6.6 Timing specification (Analog RGB)
Fig.6-1 Full/Wide/Zoom1,2 mode VSY *( ) values are for PAL mode
Non-display Line
Dot clock : 9.59MHz (9.53MHz) R,G,B 3Sub-pixles =1 clock
262.5 Line (312.5Line)
234 Line (281 Line
DipSW Selectable
50.01 s (50.36 s )
HSY 63.56 s (64.00 s ) Note: Display mode and DipSW setting can change non-display lines and display lines. Fig6-2 4:3 mode (Center/Right/Left) VSY *( ) values are for PAL mode
Non-display line
Dot clock : 7.20MHz (7.15MHz) R,G,B 3sub-pixels =1 clock
262.5 Line (312.5 Line)
234 Line (281 Line)
DipSW Selectable
50.01 s (50.36 s )
HSY 63.56 s (64.00 s ) Note: Normal left/right has same value as Normal center values as above.
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 15/27
Fig. 6-3 (Horizontal Timing (NTSC/PAL) 1 LINE=63.56(64.00) s HSY 0.7Vp-p 4.7 s
R,G,B
1.0Vp-p
Display Area
DipSW Selectable
50.01(50.36) s
Note : All values are set at typical. Values within ( ) are values for PAL mode. Fh=15.734(15.625) kHz
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 16/27
Fig.6-4 Vertical Timing (NTSC: Full/4:3mode)
Line No.
524 525 1 2 3 4 5 6 7 8 9 10 11 20 21 22 23 24 25 26 27 28 29 30
VSY HSY
0.7 Vp-p
0.7 Vp-p
R,G,B Display Area
1.0 Vp-p
DipSW Selectable (12 ~ 19H)
Line No. VSY HSY R,G,B
245 246
254 255
262 263 264 265 266 267 268 269 270 271 272 273 274 275
284 285
0.7Vp-p
Display Area
DipSW Selectable DipSW Selectable
Note: Wide/Zoom mode has different starting location
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 17/27
6.7 Video Board Adjustment
6.7.1
Dip Switch (SW 1,2)
Contents
Horizontal Display Starting Position Adjust(From HSY)
Dip Switch Number SW1
Remark Default Set SW1-1 : ON SW1-2 : OFF SW1-3 : ON SW1-4 : OFF SW1-5 : OFF SW1-6 : OFF SW1-7 : OFF SW1-8 : ON
SW1
(
4321 OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF OFF OFF ON ON OFF ON OFF OFF OFF ON OFF ON OFF ON ON OFF OFF ON ON ON ON OFF OFF OFF ON OFF OFF ON ON OFF ON OFF ON OFF ON ON ON ON OFF OFF ON ON OFF ON ON ON ON OFF ON ON ON ON
Wait Time 7.3000uS(8.5000uS) 6.9875uS(8.1875uS) 6.6750uS(7.8750uS) 6.3625uS(7.5625uS) 6.0500uS(7.2500uS) 5.7375uS(6.9375uS) 5.4250uS(6.6250uS) 5.1125uS(6.3125uS) 4.8000uS(6.0000uS) 4.4875uS(5.6875uS) 4.1750uS(5.3750uS) 3.8625uS(5.0625uS) 3.5500uS(4.7500uS) 3.2375uS(4.4375uS) 2.9250uS(4.1250uS) 2.6125uS(3.8125uS)
) values are for PAL mode, other values at side black
Vertical Display Starting Position Adjust(From VSY)
SW1
7 6 5 Start Line=12H OFF OFF OFF 12H(24H) OFF OFF ON 13H(25H) OFF ON OFF 14H(26H) OFF ON ON 15H(27H) ON OFF OFF 16H(28H) ON OFF ON 17H(29H) ON ON OFF 18H(30H) ON ON ON 19H(31H)
(
) values are for PAL mode, at zoom add31H(35H)
SW1-8: Display Image Adjustment Select ON: Internal by Pots. OFF: External by level SW2-1: ON(Default) SW2-2: ON(Default) SW2 SW2-3: UOS(Under On Screen) Display Select ON: Active OFF: Non Active SW2-4: Synchronous Signal Select ON: Composite OFF: Analog RGB
Default Set SW2-1 : ON SW2-2 : ON SW2-3 : OFF SW2-4 : ON
6.7.2
Symbol VR301 VR302 VR305 VR312
Potentiometers for Display Image Adjustment
Contents TINT: Tint Adjustment COLOR: Color Adjustment CONT: Contrast Adjustment BRT: Brightness Adjustment Remark
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 18/27
7.Product St andard 7.1.Mechanical Testing 7.1.1.External appearance
Inspection Area Item Surface Linear Scratches Surface Sport Scratches Back Scratches Chipped Dirt Criteria Thickness Disregard under 0.05mm Between 0.05mm-0.15mm, total length must be within 50mm Greater then 0.15mm is not acceptable Disregard under 1 sub-pixel Penalized for 1-3 sub-pixels Shall not exceed 3 sub-pixels Observe from surface and judge based on criteria of surface It must not influence surface Must be removable Thickness Disregard under 3.0mm Greater then 3.0mm must have less then 90mm total Diameter Less then 3.0mmf ,only 3 is allowed Greater then 3.0mmf is not accepted Must be removable Not allowed Remove as much as possible No crack or disconnection No noticeable distortion The FPC should not be coming off for more then 10mm Remark
TFT Cell Section
Note1 Note2
Discoloration No irregular discoloration on screen
Linear Scratches Metal Shield case (Applies to all surface) Spot Scratches Dirt
Deformation Fingerprint
Note2
Input Output Crack Section Distortion (FPC w/B/L Cable) FPC tape
Note3
Note1: Cell section's area subject to quality display area. Quality display area is specified in the external appearance drawing. Note2: If there are any other problems please follow "Precautions under operation". Note3: This is provisional standard and applies to limited sample (Optrex standards)
7.1.2.Dimensional Outline
All standards follow the measurement designated by the dimensional outline drawing.
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 19/27
7.2.Quality of Display
7.2.1.Conditions for Common Inspection
Unless specified, the conditions below will be applied. Ta=255? ? Humidity=65%? VPW=VBL=+12.0V? VSS=0V? Backlight inverter=Our standard inverter or equivalent, measured after backlight bas been lit for more then 30 minutes.
7.2.2.Quality Display Standard and Criteria for Judgement ( A ) Quality Display Standard
Item
Line defect Black, white and colored line Lighting irregularities due to sub-pixels by the TFT and CF. Quality Display
Refer to
Description
Criteria
Not accepted
Spot defect
White spots: Any pixel that can be seen through ND(Neutral Density) filter when black signal(Vsig=4V) is inputted under specified condition. Black sports: Any pixel that is below 50% of maximum luminance when white signal(Vsig=0V) is inputted. Luminance irregularities and discoloration spots. Same as stain with more area. Same as stain but in linear shape. Same as stain, but in arc, spirals, or moire shape. Others that are formed from concentration of irregular patterns.
next section Note 2
Stain Irregularity Quality Screen Line Stripe Reverse
Note 1,2
Note1: The quality of screen is set at Vsig=0V(white),2V(middle),4V(black)screen display and it may not be seen through 2.5% ND filter. However, for few exceptions, Sample under Optrex standard will be used for inspection. Note2: When questions arise concerning this specifications or new problems that are not specified, it will be discussed for solution.
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 20/27
8.Reliability Test 8.1.Mechanical and Environmental Test
Item Condition Test hour Remark 192 hrs 192 hrs 192 hrs 192 hrs 192 hrs 360 hrs Note2 Note1 Note1 Note1 Note1 Note1
High temp operation Ta=652? , 45%RH Below High temp & high humidity operation Low temp operation High temp storage Low temp storage Light resistance Drastic temp change Condensation
Ta=652? , 902%RH, No Condensation Ta=-303? Ta=852? , 45%RH below Ta=-403? Sunshine carbon arc Ta=632?
Endurance Heat Electrical Mechanical
-30? (60min)? 25? (15min)? 80? (60min), No electric path 20 cycle -30? (30min non-operating), 25? /95%RH(10min operating) Dried after specified cycle and confirm operation 1cycle= 48hrs non-operational
65?
10cycle
Humidity cycle
25? 0?
2.5 2.5 3 2.5 2.5 3 2.5 3
2.5 2.5 3 2.5 2.5 3 2.5 90~ 95%RH
8 hrs
5cycle
Static resistance
C=200pF, R=0O , V=150V 3 discharge on electric and other terminal, non-operational C=150pF, R=150O , V=15kV Discharge chrages 5 times each on panel and earth, nonoperational 5~ 10Hz, width 25mm 10~ 30Hz, 3.7x9.8m/s2 X,Y,Z all dir 30~ 50Hz, 1.6x9.8m/s2 8minx2sweep 50~ 80Hz, 0.7x9.8m/s2 non-operational 80~ 100Hz, 0.3x9.8m/s2 980m/s2, t=6ms, X,Y,Z all dir2,semi-sine-wave, nonoperational Apply 500g of weight perpendicular to end of terminal Onon-operational Apply pressure on the center of the screen by push/pull gauge. head diameter isf 12mm? pressured apply 5x9.8N(=5kgf) once, non-opreatioal 5x104 Pa(=0.5Pressure)? non-operational
-
Electric discharge
-
Vibration
All dir 96 hrs
Shock Terminal durability
2 hrs
External durability Pressure resistance
Note 1: High temperature operation, high temperature & high humidity operation, low temperature operation, high temperature storage and low temperature storage will test it's ability for 1000 hours to confirm. The deteriortion of plarizer is disregarded. Note 2: Drastic tempertaure change test will continue the inspection under same condition consecutiely to confirm it's ability. Test will be done mounted in your request kit.
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 22/27
8.2.Reliability Test Standard
Optical & Electrical Characteristics Item
High temp operation* High temp & high humidity operation* Low temp operation* High temp storage* Low temp storage* Light resistance* Drastic temp change*
Contrast Surface luminance >30 >25 >30 ? ? ? ? >25 ?
Response Circuit time within20% within20% Within+ 40% ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?
Quality of Screen Not to be conspicious ? ? ? ? ? ? ? ?
Endurance Heat Electrical Mechanical
Condensation? Temp.& Humidity cycle?
Static resistance
No abnormalities in system and display.
Electric discharge
No damage should be done No abnormalities in system and display. No abnormalities in system and display. No abnormalities in system and display. No abnormalities in system and display.
Vibration Shock Exterior durability Pressure durability
Note: * indicates that test was performed in room teperature, more then 2 hours after it was taken out from chamber. ? indicates that test was performed after 24 hours after it has been taken out from chamber. Luminance, circuit, response time changes are compared from the initial standard values.
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 23/27
9.Code System of Production Lot 9.1.Production Lot Number
Module's production Lot Number will be indicated as below. ? ? ? ? ? ?
Factory Number (number) Factory Code (Alphabet & Number) Week of Manufacture( 1 ~ 5 ) Month of Manufacture( 1 ~ 9 , X , Y , Z ) Year of Manufacture( Lower 2 digits)
9.2.Type Number
The type number of module is specified on the back of module as follows; T-51440GL070HU-FW-A-AC
Silk Screen Print
9.3.Precautions under Operation
When questions arise concerning this specifcations or new problems not specified in this specifications arise, problems related to the specification is to be discussed for solution.
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 24/27
10.Packing Specification
TBD
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 25/27
11.Product Handling Cautions
In order to use the products properly please note the following precautions. 1) For LCD screen ? LCD particles used in LCD module is made into form of glass board. Do not apply any strong physical shock. If it cracks, handle with extra caution to avoid any harm. ? The polarizer attached on the surface of LCD particles are composed by soft materials. Please do not scratch them.
2) Handling LCD module (static electricity countermeasure) ? Please ground all human bodies and electrical facilities. Also on the operation line, anti-static electricity mat (rubber) is recommended to avoid electric shock in case of accident. ? Working uniform should avoid synthetic fiber and recommend the use of cotton or non-electrical conducting fiber. ? When removing protective film from LCD panel, please remove it slowly to avoid development of static electricity. 3) For Storing Single LCD module for long term ? Do not store under high temperature and high humidity. ? Do not expose the module to direct sunlight or intensive ultraviolet rays for many hours. ? Avoid any force applied from external environment. 4) LCD module does not have circuit for over current protection. power supply with over current protection. For in case of accident, please use
5) If LCD panel breaks, it is possible that the liquid crystal leaks from the panel. Avoid putting it into eyes or mouth. When liquid crystal sticks on hands, clothes, or feet. Wash it out immediately with soap. 6) When using product with metal holder, if metal holder and the body are not soldered, sooth electric flow is not guaranteed. To secure the flows of electricity, please consult. 7) For products that requires the use of C F L ? On the connection of CFL cable more then 1000 v high voltage is applied. Please handle with care to avoid any burn upon contact. ? Please be careful if overcoat of CFL cable is in the status of abrasion by the contact with the system. ? Continuous use of CFL at low temperature, will shorten longevity of CFL compared to it's use at room temperature. 8) For products that uses touch panel ? Do not stack panel on top of each other. There may be possibility of harm caused by the edge of panel. ? Do not place any heavy objects above panel.
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 26/27
9) For product that uses COG, TAB, and COF ? The back side of IC hip is exposed and has low intensity. Upon handling, do not apply powerful pressure to the IC chip. ? IC chip backside is exposed and should not be equipped with any setup that releases electrical contact to prevent electrical damage. Also to prevent unintentional function by light and to keep it's electrical characteristics, set up to avoid exposure to light. 10) For product that uses FPC, heal seal and TAB ? To maintain reliability, do not hold onto connection section. Do not bend or pull lines with strong power. It could snap the lines.
12. Condition for Guarantee.
Our product is designed and manufactured by your specification requirement as a part for final electrical products. We will guarantee the product has no sign of defect and meet all qualifications of your request. However, if the final product was not for common household use, but instead used for medical, nuclear controller, aviation, disaster prevention or any other products that require extreme reliability, we can not be held responsible for any quality guarantee issue. If the product was placed for any of the use above, we ask for revision on our contract for manufacturing this product. 1) After delivery, any modification (including restructure and taking apart) of the product we can not hold any responsibility for quality guarantee issue. 2) Any damage caused by the outside force, we can not hold any responsibility for quality guarantee issue. 3) After completing all product inspection and after delivery from the factory, any static electricity applied on product, we can not hold any responsibility for quality guarantee issue. 4) Upon using product with CFL, longevity and luminance may altar by the performance of inverter or leakage. We can not hold any responsibility for quality guarantee issue by performance or reliability of final product. 5) Any product that uses our product within, we will not hold any responsibility for any problems that has no relationship with the structure or performance of our product.
T-51440GL070HU-FW-AC
OPTREX
OPTREX CORPORATION
Page 27/27


▲Up To Search▲   

 
Price & Availability of T-51440GL070HUFWAC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X